How to avoid idling of a mag drive pump

Sep 23, 2022 Leave a message

Why can't the magnetic pump run idly, under what circumstances will it cause the magnetic pump to run idly, and how can we avoid the idling of the magnetic pump?


The reason why the acid and alkali resistant magnetic pump cannot be idling
1. The magnetic pump cannot be idling, because the magnetic cylinder of the magnetic pump is cooled by the medium, if it is idling, the magnetic cylinder will be locked.
2. The bearings of the rotor of the magnetic pump are mostly made of cemented carbide and lubricated by the medium. The pump cannot be turned on without lubrication.
3. After the pump is idling, because there is no material to cool the pump, it may directly burn through the diaphragm sleeve.
4. The core components of the magnetic pump are the outer magnetic assembly and the inner magnetic assembly. If it is idling, it will cause the core components to be demagnetized at high temperature, and the performance of the magnetic pump after demagnetization will be greatly reduced.


Factors causing idling of magnetic pump and corresponding preventive measures
1. Reasons for insufficient traffic:
Insufficient flow of the acid and alkali resistant magnetic pump is mostly due to leakage of the suction pipe and the bottom valve; the water inlet is blocked; the bottom valve is not enough to enter the water; the speed of the magnetic pump is too low;
Treatment method: Check the suction pipe and the bottom valve to block the air leakage source; clean up the sludge or blockage at the water inlet; the water inlet depth of the bottom valve must be greater than 1.5 times the diameter of the water inlet pipe, and increase the water inlet depth of the bottom valve; check the power supply voltage, Increase the rotational speed of the magnetic pump, replace the sealing ring or impeller; lower the installation position of the acid and alkali resistant pump, or replace the high-lift pump. In this case, the magnetic pump is idling due to insufficient flow. The two filters are directly connected. The first one is a bag filter and the second one is a cotton core filter. The pumps equipped with the two filters are magnetic pumps with the same power of 2.2KW (3HP), and their flow requirements are the same. When the potion is filtered from the No. 1 filter magnetic pump to the No. 2 filter, the flow rate will inevitably decrease, so the liquid flowing out is not enough to be pumped by the magnetic pump in the No. 2 filter. After working for a period of time, the No. 2 magnetic pump will There will be no water idling due to insufficient flow, and finally the pump will be damaged.
2. Start the operation before the magnetic pump is filled with water? Be sure to check whether the magnetic pump is filled with water before turning on the pump, otherwise the magnetic pump will run dry without water and cause damage.
3. The foreign matter is stuck in the impeller, which causes the magnetic pump to generate vibration and noise, reduce the efficiency, reduce the flow, and then cause the magnetic pump to idle and cause the pump to be damaged. Debris should be removed in time to keep the pump running smoothly.

https://www.wxxjyby.com/