How to choose lining material for corrosive chemical pumps?

Nov 12, 2025 Leave a message

1. First Define the Corrosive Medium
Before choosing lining material, confirm 4 key parameters:
* Chemical type: acid, alkali, solvent, salt, oxidant
* Concentration: dilute vs concentrated
* Temperature: higher = stronger corrosion
* Solids content: abrasive or clean liquid
These determine material compatibility, temperature resistance, and wear resistance.

 

2. Most Common Lining Materials & Their Applications

PP (Polypropylene) Lining * Best for: Dilute acids, general corrosive wastewater, neutral media
* Temperature: ≤ 70°C
* Advantages: Low cost, good chemical resistance, lightweight
* Limitations: Poor high-temperature resistance; not for strong solvents or oxidizers
PVDF (Kynar) Lining * Best for: Strong acids (sulfuric, hydrochloric), chemicals, high-purity fluids
* Temperature: ≤ 90–100°C
* Advantages: Excellent corrosion resistance, good mechanical strength
* Limitations: Higher cost than PP
PTFE / PFA Lining * Best for: Extreme corrosion, strong oxidizers, high-temperature chemicals
* Temperature: up to 120–150°C
* Advantages: Universal corrosion resistance (king of chemical resistance)
* Limitations: High cost; needs good bonding to avoid liner separation
FRP / Fiberglass Lining * Best for: Large chemical pumps, acid circulation, low-pressure systems
* Temperature: ≤ 80–100°C
* Advantages: Corrosion-resistant, lightweight, low cost for big pumps
* Limitations: Not for high pressure or strong impact
Rubber Lining (Natural Rubber / EPDM) * Best for: Dilute acids, slurries, abrasive + corrosive fluids
* Temperature: ≤ 60–80°C
* Advantages: Good abrasion resistance
* Limitations: Poor solvent resistance

 

3. Key Selection Principles
① Compatibility First
The lining must not:
* dissolve
* swell
* soften
* crack
* delaminate
Always refer to chemical resistance table or perform material testing.

 

② Temperature Resistance
Temperature is the second most critical factor.
* High temperature accelerates corrosion and liner failure.
* Select material with higher temp rating than actual working temperature.

 

③ Abrasion Resistance
For fluids with solids:
* Choose wear-resistant lining: rubber, high-density PVDF, PFA
* Avoid brittle or soft lining that wears quickly.

 

④ Lining Process Quality
* Uniform thickness
* No bubbles, no gaps
* Strong adhesion to pump casing
* No pinholes (must pass spark test)
* Poor lining = early failure, even with good material.

 

⑤ Pressure & Vacuum Resistance
* PTFE/PFA linings need good bonding to avoid collapse under vacuum.
* For vacuum service: choose integrally molded or metal-supported liners.

 

4. Quick Selection Guide (Most Practical)

Fluid Type Recommended Lining
Dilute acid, wastewater PP
Strong acids (H₂SO₄, HCl) PVDF
Extreme corrosion, high temp PTFE / PFA
Abrasive slurry + corrosion Rubber
Large low-pressure chemical pumps FRP

 

5. Why Lined Pumps Are Better Than All-Metal Pumps

* Metal alloys (Alloy 20, Hastelloy) are very expensive.
* Lined pumps:
Low cost
Universal corrosion resistance
Lightweight
Easy to maintain
Suitable for almost all chemical media

 

https://www.xjy-pump.com/