1. Before using the pump, carefully check whether the cable is damaged, whether the fasteners are loose or falling off, and whether the pump is deformed or damaged during transportation, storage, and installation.
2. Use a 500V megohmmeter to measure the insulation resistance between the same and relative ground of the electric pump motor, and the value should not be less than 2 megohms, otherwise the stator windings of the motor should be dried, and the drying temperature should not exceed 120 ℃.
3. The installation of this series of pumps has two types: fixed type and mobile type. When the fixed automatic installation is adopted, the chain cables should be passed through (deviate from the pump water outlet, and the connection line should be parallel to the pump water outlet) two lifting ring screws or lifting plates to lift the electric pump up and down. Slide down the rail evenly and slowly until the automatic coupling is in place. When using mobile installation, first cover the hose, and use the chain cable to pass through the two rings to lift the electric pump up and down. Be careful not to use the cable as a rope to avoid danger.
4. The rotation direction of the pump after it is turned on is clockwise from the water inlet. If the electric pump is reversed, just switch any two wires in the cable to the wiring position.
5. The casing ground wire of the electric pump must be properly connected in strict accordance with the relevant regulations. In order to ensure personal safety during use, it is strictly forbidden to install the electric pump nearby, do work or move it in the water when the electric pump is running, in case the electric pump leaks. Accident occurs.
6. The electric pump must be equipped with a fully automatic water pump control cabinet without special circumstances. Do not directly connect to the power grid or use a knife switch to connect the power supply to ensure the normal operation of the electric pump.
7. Do not run the electric pump in a low head state for a long time (generally the head should not be lower than 60* of the rated head), and control it within the recommended head range to prevent the electric pump from burning out the motor due to overloading.
8. The pump without self-circulating cooling device is strictly prohibited to run above the water surface for a long time to prevent the electric pump from being damaged by overheating.