Regarding the magnetic pump with no dynamic seal and no leakage, its principle and structural characteristics were specifically introduced in the previous article, and compared with the canned motor pump.
In this issue, we focus on a detailed introduction to the structure of magnetic pump parts and common fault analysis and troubleshooting.
Parts structure analysis
The structure of the magnetic pump and the components of the magnetic pump: The magnetic pump is composed of a pump, a magnetic drive and a motor, and the magnetic drive is composed of an outer magnetic cylinder, an inner magnetic cylinder and a non-magnetic isolation sleeve.
The structure of the magnetic pump is similar. It mainly depends on how long the magnetic performance of the magnetic block is maintained.
At present, there are many magnetic materials available for magnetic pumps. Commonly used are ALNICO, ferrite and rare-earth permanent magnet materials such as SMCO5 (1:5 for short), SM (CO, CU, FE, ZR) 7.4 (for short) 2:17), ND-FE-B, etc.
Among them, the rare earth permanent magnet materials are the most preferred. The most powerful is the hinged iron boron ND-FE-B, which has a maximum magnetic energy product of more than 28X104T·A/M and an internal observation coercivity of more than 1120KA/M, which is very popular. However, the working temperature cannot exceed 120℃. Under high temperature conditions, the permanent magnet material can be used. The magnetic energy product of SM (CO, CU, FE, ZR) 7.4 is about 192X103T·A/M, and its working temperature can be as high as 300℃.
The following is the detailed structure of different types of magnetic pumps commonly available in the market:
1. Shell part: It is composed of pump body, pump cover, etc., which bears the full working pressure of the pump; the hydraulic form of the pump body impeller conforms to the API685 standard, which is the main characterizing component of the hydraulic performance of the magnetic pump. Its function is to force the liquid to rotate. Thereby converting the mechanical energy of the prime mover into liquid energy.
2. Rotor part: divided into rotating parts installed on the pump shaft and rotating parts installed on the drive shaft. The pump shaft is an important part that carries the impeller and the inner rotor and transmits torque.
The rotating parts installed on the pump shaft consist of the impeller, bearings, thrust ring components, internal magnetic rotor components, etc. plus the pump shaft itself to form the rotor part that is in contact with the medium.
The rotating parts installed on the drive shaft consist of external magnetic rotor components, rolling bearings, drive shaft sleeves, etc. plus the drive shaft itself to form the part of the rotor in contact with air.
3. Connecting part: a static connecting piece which is composed of a connecting frame, a bearing box, etc., which plays a role of connecting and supporting. Sliding bearing, shaft sleeve and thrust plate: it is the supporting and positioning parts of the pump rotor system.
4. Transmission part: The pump and the prime mover are connected by a diaphragm-type extension coupling component. During maintenance, only the middle diaphragm of the coupling is removed to perform the maintenance of the magnetic pump.
5. Inner and outer rotors: the inner and outer rotors are used together to form the magnetic drive part of the magnetic pump.
6. Isolation sleeve: Isolation sleeve is the only part that can completely realize that the magnetic pump is completely leak-free.
Because the pump shaft is in contact with the medium, the material requirements are corrosion resistance, high processing accuracy, high strength or increase the strength of the material through heat treatment.
The magnetic coupling of the magnetic pump is integrated with the pump body, so the structure is compact, maintenance is convenient, safe and energy-saving. The magnetic coupling of the pump can protect the transmission motor from overload.
Magnetic pump profile display
Guardian magnetic drive pump
CPXS magnetic drive pump
Polychem M series fluorine plastic lined magnetic pump
ERPN cantilever magnetic drive pump
PVML cantilever vertical magnetic drive pipeline pump
Fault analysis and troubleshooting
The advantage of the magnetic pump is that there is no leakage, which completely solves the problem of "running, emitting, dripping and leaking".
But the disadvantages of the corresponding magnetic pump are:
1. High requirements for alignment
2. When the inlet material is not clean, it is easy to wear the inner magnetic cylinder and isolation sleeve
3. The material requirements for the isolation sleeve of the magnetic pump are relatively high.
4. The magnetic pump is not allowed to run without material
5. The efficiency of magnetic pump is lower than ordinary centrifugal pump
6. The price is relatively expensive.
7. Restrictions on the scope of use: the use of the magnetic pump in the working environment of the pump, the ambient temperature, motor temperature, maximum working pressure, medium density and particle requirements, etc.
8. Long-term use, even if the mechanical parts are not damaged, it may still be unable to continue to use because of the weakened magnetic force.
Therefore, the precautions for using the magnetic pump are as follows:
(1) After installation, turn the coupling by hand to check for rubbing.
(2) In order to prevent debris from entering the pump, a filter is installed at the inlet of the pump, and the filter area is 3-4 times larger than the cross-sectional area of the pipeline.
(3) Dry operation is strictly prohibited.
(4) Pumps with high lift heads should be equipped with check valves on the outlet pipes to prevent water hammer from sudden shutdown.
(5) Procedure for starting the pump: Open the inlet valve before driving and fill the pump with the liquid to be conveyed; close the outlet valve; turn on the electric hoist to check whether the steering of the pump is correct; after the pump is started, the outlet valve should be opened slowly. After the pump reaches the normal operating state, adjust the outlet valve to the required opening. Test run for 5-10min, if there is no abnormality, it can be put into operation.
Shutdown procedure: close the outlet valve; cut off the power supply; close the inlet. When the pump is not in use for a long time, clean the flow passage in the pump and cut off the power supply.
magnetic pump
Maintenance notes
(1) The pump shaft is broken.
The material used for the pump shaft of the CQB magnetic pump is 99% alumina porcelain. The main reason for the pump shaft breaking is that the shaft is twisted due to the dry running of the pump and the dry grinding of the bearing. When the pump is disassembled and inspected, it can be seen that the bearings have been severely worn. The main way to prevent the pump from breaking is to avoid the dry running of the pump.
(2) The bearing is damaged.
The bearing material of CQB magnetic drive pump is high-density carbon. If the pump is cut off or there are impurities in the pump, the bearing will be damaged. If the coaxiality requirements between the inner and outer magnetic rotors of the cylindrical coupling cannot be guaranteed, it will directly affect the life of the bearing.
(3) The pump cannot pump liquid.
The failure of the pump to produce liquid is the most common failure of the pump, and there are many reasons for it. First of all, check whether the suction pipe of the pump is leaking, check whether the air in the suction pipe is discharged, whether the amount of liquid filled in the pump is sufficient, whether there is debris in the suction pipe, and check whether the pump is reversed ( Especially after the motor has been changed or the power supply line has been overhauled), pay attention to whether the suction height of the pump is too high. If you still cannot solve the problem through the above inspections, you can disassemble the pump and check to see if the pump shaft is broken. You should also check whether the moving and static rings of the pump are intact, and whether the entire rotor can move a little axially. If the axial movement is difficult, check whether the carbon bearing is too tightly combined with the pump shaft.
It is worth noting that the pump has been repaired several times and no problems can be found, and attention should be paid to whether the magnetic coupling is working properly. Bearings, inner magnetic rotors and spacers all generate heat during operation, which will increase the working temperature, on the one hand, reduce the transmitted power, on the other hand, it will cause a lot of trouble for pumps that transport easily vaporized liquid. The power transmitted by the magnetic steel is a continuous decline curve with the increase of temperature. Generally, below the working limit temperature of the magnetic steel, the reduction of its transmission capacity is reversible, and it is irreversible above the limit temperature, that is, the magnetic steel is cooled. Later, the lost delivery capacity can no longer be restored. Under special circumstances, when the magnetic coupling slips (out of step), the eddy current heat in the spacer will increase sharply and the temperature will rise sharply. If it is not handled in time, it will cause the magnetic steel to demagnetize and make the magnetic coupling fail. Therefore, the magnetic pump should be designed with a reliable cooling system. For the medium that is not easy to vaporize, the cooling circulation system usually draws the liquid flow from the impeller outlet or the pump outlet, and returns to the suction port through the bearing and the magnetic transmission part. For the medium that is easy to vaporize, a heat exchanger should be added or the liquid flow should be led out of the pump. To prevent the heat from returning to the suction port, consider filtering the medium with solid impurities or ferromagnetic impurities, and consider cooling for high-temperature media to ensure that the magnetic coupling does not exceed the operating limit temperature.
When considering whether the rotation speed is sufficient, first check whether the rotation speed of the motor itself is normal, which can be measured with a tachometer. When the rotation speed of the motor is normal, consider whether there will be slippage of the magnetic coupling.
(4) Insufficient head.
The reasons for this failure are: there is air in the conveying medium, the impeller is damaged, the speed is not enough, the specific gravity of the conveying liquid is too large, and the flow is too large.
(5) Insufficient flow.
The main reasons for insufficient flow are: impeller damage, insufficient speed, excessive lift, and clogging of debris in the pipe.
What are the well-known companies of magnetic pump?
If you know more about magnetic pump manufacturers, please leave a message.
Thank you for visiting the website of the professional manufacturer of Wuxi Xinjiuyang Pump Industry. If you have any questions, you can call our sales hotline: 021-56908228 56304161 56633982, we will do our best to provide you with quality service.
Wuxi Xinjiuyang Pumps does not yield to price pressure in terms of product quality. Although market competition is fierce, it will never reduce product quality. Three guarantees for product quality (repair, replacement, and return) are implemented for one year, and spare parts will be provided free of charge due to product quality problems (repair, replacement) within one year, and cost will be charged as appropriate after one year. Wuxi Xinjiuyang The pump company provides lifetime warranty and accessories. If we are unable to deal with the quality problem, we will refund within one year.
The after-sales service department of Wuxi Xinjiuyang Pump Industry will establish after-sales service tracking files for users, check regularly every month, collect feedback in time, and improve the quality of products.
The business tenet of Wuxi Xinjiuyang Pump Industry is to "rely on science and technology to create the Hongdong brand, and to win customer satisfaction with quality". In order to ensure that users can rest assured and use the company's products normally, the following rules are formulated as the company's after-sales service commitment:
1. The products produced by our company have reached strict corporate standards and the standards of the Ministry of Machinery.
2. After receiving the order notification, the company will deliver the goods in strict accordance with the relevant provisions of the contract clauses to ensure that the products are intact and delivered at the required time and place.
3. During the warranty period, if the product is indeed damaged or not working properly due to quality problems, our company is responsible for free repair or replacement, and provide relevant maintenance knowledge; if the damage is caused due to improper use by the user or outside the warranty period Damaged or abnormal work, the company provides lifetime maintenance services for the product. If the user needs, the company provides free consultation and on-site guidance for installation and commissioning.
4. For users who have problems or information in the process of using our products, please give feedback to our company in time, so that our company can deal with it and improve it in time. The company provides high-quality after-sales service, and customers' questions must be answered or resolved within 6 hours.
https://www.wxxjyby.com/