The Working Principle Of Magnetic Pump And The Maintenance Method Of Common Failure

Aug 27, 2020 Leave a message

139

Introduction to Magnetic Pump

At present, the magnetic pumps of domestic manufacturers can be roughly divided into several categories: stainless steel magnetic pumps, engineering plastic magnetic pumps, fluoroplastic magnetic pumps, and high temperature resistant magnetic pumps. It is widely used in industries such as fine chemicals, biomedicine, pesticide medicine, electroplating wastewater, steel smelting, pickling and polishing.

The magnetic pump is composed of three parts: pump, magnetic drive and motor. The key components of the magnetic drive are composed of an outer magnetic rotor, an inner magnetic rotor and an isolation sleeve.

The working principle of magnetic pump and the maintenance method of common failure

The working principle of magnetic pump and the maintenance method of common failure

When the motor drives the outer magnetic rotor to rotate, the magnetic field can penetrate the air gap and non-magnetic materials, and drive the inner magnetic rotor connected to the impeller to rotate synchronously, realizing the contactless transmission of power and transforming the dynamic seal into a static seal.

Because the pump shaft and inner magnetic rotor are completely enclosed by the pump body and the isolation sleeve, the problem of "running, emitting, dripping, and leaking" is completely solved.

The working principle of magnetic pump and the maintenance method of common failure

The working principle of magnetic pump and the maintenance method of common failure

Working principle of magnetic pump

N pairs of magnets (n being an even number) are assembled on the inner and outer magnetic rotors of the magnetic drive in a regular arrangement, so that the magnet parts form a complete coupled magnetic system with each other.

When the inner and outer magnetic poles are opposite to each other, that is, the displacement angle between the two magnetic poles is Φ=0, the magnetic energy of the magnetic system is low at this time; when the magnetic poles rotate to the same pole, the displacement angle between the two magnetic poles is Φ=2π /n, the magnetic energy of the magnetic system is large at this time. After removing the external force, since the magnetic poles of the magnetic system repel each other, the magnetic force will restore the magnet to a state of low magnetic energy. Then the magnet moves and drives the magnetic rotor to rotate.

The working principle of magnetic pump and the maintenance method of common failure

The working principle of magnetic pump and the maintenance method of common failure

Analysis of important parts of magnetic pump

1. Permanent magnets

Permanent magnets made of rare earth permanent magnet materials have a wide operating temperature range

(-45-400℃), the coercive force is high, the magnetic field direction has good anisotropy, the demagnetization phenomenon will not occur when the same pole is close, it is a good magnetic field source.

The working principle of magnetic pump and the maintenance method of common failure

The working principle of magnetic pump and the maintenance method of common failure

NdFeB magnetic strength (above)

The working principle of magnetic pump and the maintenance method of common failure

The working principle of magnetic pump and the maintenance method of common failure

Ferrite magnetic strength (above)

2. Isolation sleeve

When a metal isolating sleeve is used, the isolating sleeve is in a sinusoidal alternating magnetic field, which induces eddy currents in the cross section perpendicular to the direction of the magnetic force and converts them into heat (public number: pump housekeeper).

The isolation sleeve is made of non-metallic materials with high resistivity and high strength, which is very effective in reducing eddy current.

The working principle of magnetic pump and the maintenance method of common failure

The working principle of magnetic pump and the maintenance method of common failure

The picture above shows the stainless steel isolation sleeve (with magnetic eddy current)

The working principle of magnetic pump and the maintenance method of common failure

The working principle of magnetic pump and the maintenance method of common failure

The picture above is a non-metallic isolation sleeve (no magnetic eddy current)

3. Cooling lubricant flow control

When the pump is running, a small amount of liquid is used to wash and cool the annular gap area between the inner magnetic rotor and the isolating sleeve and the friction pair of the sliding bearing.

The flow of the coolant is usually 2-3 of the design flow of the pump, and the annular gap area between the inner magnetic rotor and the isolating sleeve generates high heat due to eddy currents.

When the cooling lubricant is insufficient or the flushing hole is not smooth or blocked, the temperature of the medium will be higher than the working temperature of the permanent magnet, and the inner magnetic rotor will gradually lose its magnetism and the magnetic drive will fail.

When the medium is water or water-based liquid, the temperature rise in the annulus area can be maintained at 3-5°C; when the medium is hydrocarbon or oil, the temperature rise in the annulus area can be maintained at 5-8°C.

The working principle of magnetic pump and the maintenance method of common failure

The working principle of magnetic pump and the maintenance method of common failure

4. Sliding bearing

The material of the sliding bearing of magnetic chemical pump includes impregnated graphite, filled PTFE, engineering ceramics, etc.

Engineering ceramics have good heat resistance, corrosion resistance, and friction resistance, so the sliding bearings of magnetic pumps are mostly made of engineering ceramics.

However, engineering ceramics are very brittle and have a small expansion coefficient, so the bearing clearance must not be too small to avoid shaft holding accidents.

The sliding bearing of the magnetic pump is lubricated by the conveyed medium, so different materials should be used to make the bearings according to different media and operating conditions.

The working principle of magnetic pump and the maintenance method of common failure

The working principle of magnetic pump and the maintenance method of common failure

Advantages of magnetic pump compared to centrifugal pump

1. The pump shaft changes from a dynamic seal to a closed static seal, completely avoiding medium leakage.

2. There is no need for independent lubrication and cooling water, which reduces energy consumption.

3. From coupling drive to synchronous drag, there is no contact and friction; low power consumption, high efficiency, and has a damping and vibration reduction effect, reducing the impact of motor vibration on the pump and the impact on the motor when the pump occurs cavitation vibration Impact.

Precautions for magnetic pump

The working principle of magnetic pump and the maintenance method of common failure

The working principle of magnetic pump and the maintenance method of common failure

1. Prevent particles from entering

(1) Ferromagnetic impurities and particles are not allowed to enter the magnetic drive and bearing friction pairs.

(2) After transporting the medium that is easy to crystallize or precipitate, flush the pump in time and pour clean water into the pump cavity after stopping the pump, and drain it after 1 minute of operation to ensure the service life of the sliding bearing.

(3) When transporting media containing solid particles, filter at the inlet of the pump flow pipe.

2. Prevent demagnetization

(1) The magnetic torque cannot be designed too small.

(2) It should be operated under the specified temperature conditions, and the medium temperature is strictly prohibited from exceeding the standard. A platinum resistance temperature sensor can be installed on the outer surface of the magnetic pump isolation sleeve to detect the temperature rise in the annulus area, so as to alarm or shut down when the temperature exceeds the limit.

3. Prevent dry friction

(1) Idling is strictly prohibited.

(2) It is strictly forbidden to evacuate the medium.

(3) When the outlet valve is closed, the continuous operation time of the pump shall not exceed 2 minutes to prevent the magnetic actuator from overheating and failing.

4. Not usable in stressful systems

Because there is a certain inter-system in the pump cavity of the magnetic pump and the "static bearing" is used in the magnetic pump, this series of pumps cannot be used in a pressure system, and neither positive pressure nor negative pressure is feasible.

Analysis of common problems of magnetic pump

1. Because the cooling and lubrication of the magnetic pump bearing depends on the medium being transported, idling is forbidden, and at the same time, avoiding idling operation caused by restarting after a power cut in the middle of work.

The working principle of magnetic pump and the maintenance method of common failure

The working principle of magnetic pump and the maintenance method of common failure

2. If the conveyed medium contains solid particles, a filter should be added to the pump inlet: if it contains ferromagnetic particles, a magnetic filter should be added.

The working principle of magnetic pump and the maintenance method of common failure

The working principle of magnetic pump and the maintenance method of common failure

3. The ambient temperature of the pump during use should be less than 40℃, and the temperature rise of the motor should not exceed 75℃.

4. The conveyed medium and its temperature should be within the allowable range of the pump material. The service temperature of engineering plastic pump is <60℃, and the service temperature of metal pump is <100℃.

Transport the liquid without hard particles and fibers with suction pressure not greater than 0.2MPa, maximum working pressure 1.6MPa, density not greater than 1600Kg/m3, and viscosity not greater than 30X10-6m2/S.

5. For the medium that is easy to precipitate and crystallize, the transport fluid should be cleaned in time after use to drain the liquid accumulation in the pump.

The working principle of magnetic pump and the maintenance method of common failure

The working principle of magnetic pump and the maintenance method of common failure

6. After 1000 hours of normal operation of the magnetic pump, the wear of the bearing and end face moving ring should be disassembled and inspected, and the wearing parts that are not suitable for reuse should be replaced.

Causes of common problems with magnetic pumps

No medium or small flow of conveying medium: dry friction between the rotor main shaft and the stable bearing, burning the bearing. The magnetic pump is lubricated and cooled by the conveying medium to the sliding bearing. Without opening the inlet valve or the outlet valve, the sliding bearing is damaged due to high temperature due to the lack of lubrication and cooling of the conveying medium.

Isolation sleeve damage: The magnetic coupling of the magnetic pump is cooled by the medium conveyed by the pump. If there are hard particles in the medium, it is easy to cause the isolation sleeve to be scratched or pierced. Sometimes if the maintenance method is improper, it may also cause the isolation sleeve. damage.

Thank you for visiting the website of the professional manufacturer of Wuxi Xinjiuyang Pump Industry. If you have any questions, you can call our sales hotline: 021-56908228 56304161 56633982, we will do our best to provide you with quality service.


Wuxi Xinjiuyang Pumps does not yield to price pressure in terms of product quality. Although market competition is fierce, it will never reduce product quality. Three guarantees for product quality (repair, replacement, and return) are implemented for one year, and spare parts will be provided free of charge due to product quality problems (repair, replacement) within one year, and cost will be charged as appropriate after one year. Wuxi Xinjiuyang The pump company provides lifetime warranty and accessories. If we are unable to deal with the quality problem, we will refund within one year.

The after-sales service department of Wuxi Xinjiuyang Pump Industry will establish after-sales service tracking files for users, check regularly every month, collect feedback in time, and improve the quality of products.

The business tenet of Wuxi Xinjiuyang Pump Industry is to "rely on science and technology to create the Hongdong brand, and to win customer satisfaction with quality". In order to ensure that users can rest assured and use the company's products normally, the following rules are formulated as the company's after-sales service commitment:

1. The products produced by our company have reached strict corporate standards and the standards of the Ministry of Machinery.

2. After receiving the order notification, the company will deliver the goods in strict accordance with the relevant provisions of the contract clauses to ensure that the products are intact and delivered at the required time and place.

3. During the warranty period, if the product is indeed damaged or not working properly due to quality problems, our company is responsible for free repair or replacement, and provide relevant maintenance knowledge; if the damage is caused due to improper use by the user or outside the warranty period Damaged or abnormal work, the company provides lifetime maintenance services for the product. If the user needs, the company provides free consultation and on-site guidance for installation and commissioning.

4. For users who have problems or information in the process of using our products, please give feedback to our company in time, so that our company can deal with it and improve it in time. The company provides high-quality after-sales service, and customers' questions must be answered or resolved within 6 hours.

140

https://www.wxxjyby.com/