Sep 19, 2022 Leave a message

1. Check whether the joints of the pump and pipeline are loose. Rotate the magnetic pump by hand to see if the pump is flexible, and then try to see the direction of the motor.

2. Add bearing lubricating oil into the suspension, and observe that the oil level should be between the two lines on the oil standard.

3. Unscrew the water diversion plug of the pump body, and irrigate and divert water.

4. Close the gate valve of the outlet pipe, the outlet pressure gauge and the inlet vacuum gauge.

5. Start the motor. When the pump is running normally, work the outlet pressure gauge and the inlet vacuum gauge. After seeing the appropriate pressure, gradually open the gate valve and check the motor load at the same time.

6. Try to control the flow and head of the pump within the range indicated on the pump label, and ensure that the pump runs for a long time near the high-efficiency point, so as to obtain excellent energy-saving effect.

7. During the operation of the magnetic pump, the temperature of the bearing should not exceed 35 degrees of the ambient temperature, and the limit temperature should not exceed 80 degrees.

8. If the pump is found to have abnormal sound, stop immediately to check the cause.

9. When the pump is to be stopped, first close the gate valve and pressure gauge, and then stop the motor.

10. In the first month of operation, the chemical pump should replace the lubricating oil after 100 hours. After every 500 hours, change the oil.

11. Regularly adjust the packing gland to ensure normal dripping in the packing chamber.

12. When the pump is used in cold winter, after parking, the drain plug at the bottom of the pump body must be unscrewed to drain the water to prevent freezing and cracking.

13. If the pump is to be out of use for a long time, it is necessary to disassemble all the pumps, dry the water, apply grease to the rotating parts and joints, and store them properly.

https://www.wxxjyby.com/