1.1 Preparations before starting the pump
1.1.1 Irrigation pump (except for submerged pumps, other pumps must be primed before the self-priming pump is started for the first time) (that is, the pumping medium must be filled with the pump cavity)
1.1.2 Reverse irrigation device: Open the stop valve of the inlet pipeline, open all the exhaust pipes, discharge the gas, slowly turn the rotor, and close the exhaust valve when the pumped medium has no bubbles.
1.1.3 Suction device irrigation pump: open the inlet line to get the shut-off valve, open all the exhaust lines, discharge the gas, pour the pump (the suction pipe must be equipped with a bottom valve), slowly rotate the rotor, when the pumping medium does not have bubbles , Close the exhaust valve.
1.1.4 Turn on all auxiliary systems, and require all auxiliary systems to work for at least 10 minutes. Wait until the entire auxiliary system is stable before proceeding to the next step. The auxiliary systems include lubricating oil system, seal flushing system, cooling and insulation System etc.;
1.1.5 Check the equipment to check whether the equipment rotates flexibly; jog the motor to judge whether the pump rotation direction is correct again; after confirmation, fix the coupling guard.
1.1.6 (machine pump with dry gas sealing system) dry gas sealing system is put into use. Open the nitrogen inlet valve to charge the sealed chamber. The air source pressure of the dry gas seal must be between 0.5 and 1.0 MPa. Each pump adjusts the pressure and flow of the sealed chamber according to specific requirements.
1.2 Starting the pump
1.2.1 Confirm that the suction valve is fully open and the discharge valve is closed or slightly open; when there is a minimum flow line, the discharge valve is fully closed and the minimum flow valve is fully open.
1.2.2 Close the outlet pipeline stop valve (minimum flow must be guaranteed);
1.2.3 Start the motor to make the pump rotor reach the running speed;
1.2.4 Slowly open the outlet valve to make the outlet pressure and flow of the pump reach the specified value. At the same time when opening the outlet valve, the motor current change should be checked to avoid motor overload. When the flow rate increases, you should also pay attention to whether there is abnormal leakage of the pump seal, whether the vibration of the pump is normal, whether there is abnormal sound of the pump body and motor, changes in outlet pressure, etc. If the pump has abnormal leakage, abnormal vibration, Abnormal noise or outlet pressure is lower than the design value, the cause should be identified and dealt with.
1.2.5 When the pump runs normally, check the pump outlet pressure, outlet flow rate, motor current, temperature of bearings and seals, oil level of the lubricant, vibration, noise of the pump, and leakage of the seals; (according to process requirements) Close the minimum flow bypass valve. Keep relevant equipment operation records.
Note:
(1) The maximum starting frequency of the pump cannot exceed 12 times/hour;
(2) The pressure difference cannot be lower than the design point, nor can it cause fluctuations in performance parameters in the system. The pump outlet pressure gauge value is equal to the pressure difference plus the inlet pressure gauge value;
(3) The reading on the ammeter at full load ensures that the current does not exceed the value on the motor nameplate;
(4) The motor equipped with the pump may be selected according to the actual requirements of the buyer according to the buyer's requirements. In the trial operation, the power of the motor should be considered. If the specific gravity of the actual medium is smaller than that of the trial operation medium, please strictly control the valve opening during the trial operation to avoid overloading or even burning the motor. If necessary, the pump manufacturer must be contacted.
1.3 Shutdown of the pump
1.3.1 Close the discharge valve slowly until the flow reaches the minimum flow.
1.3.2 Turn off the power, stop the pump, and close the outlet valve.
1.3.3 When the minimum flow bypass line is provided, close the discharge valve with the bypass valve fully open, and then cut off the power to stop the pump. The high-temperature pump can stop circulating water only when the temperature drops below 80 ℃; the sealing system (flushing liquid, sealing gas) should stop according to the situation after stopping the pump for 20 minutes.
1.3.4 Standby pump: the suction valve is fully open and the discharge valve is fully closed (when a minimum flow bypass line is provided, the bypass valve is fully open and the discharge valve is fully closed), so that the pump is in a state of full liquid suction pressure. The cooling water of the standby pump should continue to be used to keep the lubricating oil level not lower than the specified oil level. In winter, pay special attention to inspection, keep the heating cable and cooling water unblocked to avoid freezing.
1.3.5 The reserve pump should be cranked according to the regulations.
1.3.6 (After stopping) the pump that needs to be repaired, after stopping the pump (cooling down), first close the nitrogen inlet valve of the dry gas sealing system, release the pressure in the sealed cavity, and then completely discharge the liquid in the pump and the cooling water in the cooling system to make the pump The pressure drop in the body is zero, the residual materials in the pump are purged clean, all valves are closed, and the power is disconnected from the substation. On-site processing must meet HSE requirements.
1.4 Switching of centrifugal pump
When switching pumps, the principle of unchanged system flow and pressure should be strictly guaranteed, and it is strictly forbidden to evacuate or grab volume.
Switching under normal conditions:
1.4.1 The standby pump should make all preparations for starting.
1.4.2 Open the suction valve of the backup pump (filling pump, filling and exhausting), and start the backup pump according to the normal procedure.
1.4.3 Check the outlet pressure, current, vibration, leakage, temperature, etc. of the standby pump, if they are normal, you can gradually open the opening of the discharge valve, while gradually closing the opening of the discharge valve of the original running pump, try to maintain the system flow , The pressure remains unchanged. When the outlet pressure and flow of the standby pump are normal, close the discharge valve of the original running pump and cut off the power, and press the stop pump to process.
Switch in emergency:
The switching of the centrifugal pump in an emergency refers to accidents such as oil ejection, motor fire, and serious damage to the pump.
1.4.4 The standby pump should make all preparations for starting.
1.4.5 Turn off the power of the original running pump, stop the pump, and start the standby pump.
1.4.6 Open the discharge valve of the standby pump to make the outlet flow and pressure reach the specified value.
1.4.7 Close the discharge valve and suction valve of the original running pump to deal with the accident.
1.5 Daily operation and maintenance of centrifugal pump
1.5.1 Bearing temperature
The maximum temperature on the bearing housing is 80°C. General sliding bearing temperature is below 65℃; rolling bearing is below 70℃
1.5.2 Replenishment and replacement of lubricating oil
(1) Regularly check the oil level of the bearing box, if the oil level reaches the lower limit of the oil level gauge, replenish the lubricant at any time
(2) When starting operation, check the quality of the lubricant every two weeks, 2-3 times, if the lubricant deteriorates, check the quality of the lubricant every three months after changing the lubricant at any time, and replace the lubrication every 6 months oil.
1.6 Operation and precautions of centrifugal pump:
1.6.1 Centrifugal pumps are not allowed to run idly without liquid under any circumstances to avoid damage to parts.
1.6.2 Start the centrifugal pump. If the discharge valve is not open, it is not allowed to run for more than 2 minutes.
1.6.3 The discharge valve must be used to adjust the flow rate, and the suction valve must never be used to adjust the flow rate to avoid cavitation.
Machine pumps with dry gas seals should pay attention to prevent reverse rotation to prevent damage to the seal.
1.6.4 (Machine pump with external flushing) The flow rate of sealing flushing liquid is generally controlled at 8~10L/min.
1.6.5 It is strictly forbidden to run the equipment with disease, to prevent damage to the pump parts and motor overload.
1.6.6 It is forbidden to start the engine blindly before the cause of the interlock shutdown is found and the fault is eliminated.
1.7 General failures, causes and troubleshooting methods of centrifugal pumps: (see Table 1)
Table 1 Common causes and troubleshooting methods of centrifugal pumps
malfunction
the reason
elimination method
1. The pump cannot deliver liquid
1. Poor exhaust;
2. Insufficient net suction head;
3. There are cavitation in the suction piping;
4. The speed is too low;
5. The rotation direction is wrong;
6. The actual head of the system is higher than the designed head of the pump;
7. Air leakage from the sealing gland;
8. The suction valve or discharge valve is not open; the outlet check valve is damaged
9. Flowmeter failure;
10. The suction filter is blocked and the cavitation is serious;
exhaust.
Improve inhalation conditions.
exhaust.
Increase the speed.
Change the motor direction.
Adjust operation or replace with new pump.
repair.
Check and open the suction valve and discharge valve; repair the outlet check valve.
Check the flowmeter.
Clean filters; resolve cavitation
2. Insufficient discharge volume and insufficient discharge pressure
1. The pump and piping are not filled with liquid, and the exhaust is poor;
2. Insufficient net suction head;
3. Air leakage from the sealing gland;
4. The speed is too low;
5. The actual head of the system is higher than the design head;
6. The direction of rotation is wrong;
7. Impurities are blocked on the impeller;
8. (mouth ring) sealing ring wear;
9. Impeller damage (or partial blockage);
10. The suction filter is blocked;
11. Flowmeter failure;
Fully fill the liquid and exhaust.
Increase suction pressure.
repair.
Adjust to increase the speed.
Adjust operation or replace with new pump.
Adjust the motor steering.
Clean up.
Repair or replace.
Repair or replace.
Clean up.
Repair and replace the flowmeter.
3. The driver load is too large
1. The speed is too high;
2. The specific gravity and viscosity of the liquid are larger than the design value;
3. The seal ring is worn;
4. The assembly of the mechanical seal is not good;
5. Shaft bending or bearing failure and poor alignment;
6. Rotating parts and fixed parts are in contact;
Speed regulation.
Change the specific gravity and viscosity of the liquid.
Repair or replace.
Reassemble.
Overhaul.
repair.
4. Excessive vibration and noise of the pump
1. Cavitation occurs;
2. The flow is too small;
3. Poor alignment of motor and pump shaft;
4. The foundation is not strong;
5. The shaft is bent;
6. Rotating parts and fixed parts are in contact;
7. Bearing wear;
8. The impeller is damaged;
9. Bearing installation and assembly are not good;
10. Less oil, no oil or mixed water in the bearing box;
Prevent cavitation.
Increase the flow or set a bypass line.
Realign the round.
Reinforce the foundation.
Find out the reason for overhaul or replacement.
Overhaul.
Replace the bearing.
Overhaul and replace.
Reassemble the installation.
Refuel or replace the lubricant.
5. Bearing overheating
1. Poor centering;
2. The shaft is bent;
3. Vibration occurs when the rotating part is unbalanced;
4. Abnormal thrust due to mechanical damage inside the pump or malfunction of the balance mechanism;
5. There is little, too much, too dirty or mixed water in the bearing box;
6. The bearing installation and assembly are not good;
7. The bearing is seriously worn;
8. Little or no cooling water;
9. Hot weather and high temperature;
Refocus.
Check the reason to repair or replace the shaft.
Overhaul.
Refuel and change oil as required.
Reassemble the installation.
Replace the bearing.
Turn on the cooling water.
Strengthen ventilation and cooling.
6. The pump bites and overheats
1. Poor exhaust;
2. Insufficient net suction head;
3. The flow is too small;
4. Poor centering;
5. Rotating parts and fixed parts are in contact;
6. Serious bearing wear;
7. Vibration occurs when the rotating parts are unbalanced;
8. Foreign matter enters the pump;
9. Oil solidification;
Re-vent.
Increase suction pressure.
Increase traffic.
Refocus.
Overhaul.
Repair or replace the bearing.
Overhaul.
Maintenance and cleaning.
Warm up.
7. Dry gas seal leakage
1. The pressure of the air source is insufficient or too large.
2. The pump shaft is reversed;
3. Liquid in the sealed cavity;
4. The front common mechanical seal leaks at the same time
Adjust the air pressure.
Adjust the direction of rotation.
Overhaul and drain.
At the same time repair the entire set of seals
8. Serious leakage of mechanical seal
1. The piping for the mechanical seal flushing fluid is blocked;
2. The pressure of the seal letter is higher than the pressure of the flushing liquid, and the flushing liquid cannot enter the seal letter;
3. Poor alignment and poor centering;
4. The shaft is bent;
5. Bearing wear;
6. The mechanical seal assembly is not good;
7. Vibration due to unbalanced rotating parts;
8. The model of the mechanical seal is not correct;
9. Little or no cooling water;
10. The sliding surface of the mechanical seal has scratches due to the foreign matter contained in the seal flushing fluid;
11. The sliding surfaces of the static ring and the moving ring are uneven;
12. Gas is generated in the mechanical seal box to affect the operation;
13. Insufficient interference of "O" ring or inappropriate selection of materials;
14. The perpendicularity between the main shaft and the sliding surface of the mechanical seal is poor;
Repair and seal, clean and unblock pipelines.
Increase the pressure of the flushing fluid.
Re-center and refocus.
Repair or replace the shaft.
Repair or replace the bearing.
reassemble.
repair.
Replace the mechanical seal with the appropriate model.
Increase the amount of cooling water.
Replace the inspection seal and flushing fluid filter for inspection.
Check and replace the dynamic and static ring.
Exhaust prevents gas generation.
Replace the appropriate "O" ring.
Re-install.