1. Because the cooling and lubrication of the bearing of the magnetic pump depends on the medium being conveyed, it is absolutely forbidden to run without a load, and at the same time, avoid running without a load when the power is cut off and then restarted in the middle of the work.
2. If the conveyed medium contains solid particles, a filter should be added to the pump inlet; if it contains ferromagnetic particles, a magnetic filter should be added.
3. The ambient temperature of the pump in use should be less than 40℃, and the temperature rise of the motor should not exceed 75℃.
4. The medium to be transported and its temperature should be within the allowable range of the pump material (see attached table for details). The operating temperature of the engineering plastic pump is less than 60℃, and the operating temperature of the metal pump is less than 100℃. Liquids containing hard particles and fibers.
5. For the medium that is easy to precipitate and crystallize, it should be cleaned in time after use to drain the accumulated fluid in the pump.
6. After 1000 hours of normal operation of the magnetic pump, the wear of the bearing and the end face moving ring should be dismantled and inspected, and the wearing parts that should not be reused should be replaced.
7. Dry operation is strictly prohibited;
8. Thoroughly remove rust and solid foreign matter in the device;
9. The air in the pump must be removed before the pump runs;
10. The cut-off operation time shall not last for more than 60s;
11. Do not continue to run in reverse;
12. During operation, if abnormal sound or vibration is found, it is necessary to quickly find out the cause and eliminate the fault;
13. When it is less than the minimum flow, it should not run;
14. The normal working state of the pump must be within the range of performance parameters required by the contract, otherwise it will affect the axial force in the pump; the normal temperature structure magnetic pump (NdFeB magnetic material) is strictly prohibited from "high temperature" sweeping.
Precautions for the use of stainless steel magnetic drive pumps
Jun 10, 2022
Leave a message